Patents
Assignee / Organization

Landeck Danielle

108Total Forward Citations
8Indexed Patents
14Avg Citations / Patent
5Portfolio H-Index
US 2013006267 A1#1602674 Most Cited · 37 citations2.9/yr · PR 5.33PendingUS · Application
Surgical Robotic Systems with Manual and Haptic and/or Active Control Modes

A surgical robotic system is disclosed that provides a combination of a programmed control, such as active control or passive control, when a high degree of accuracy is required and manual control when a high degree of accuracy is not required, such as during the removal of…

US 8,498,744 B2#8724205 Most Cited · 12 citations0.9/yr · PR 1.44ActiveUS · Utility
Surgical robotic systems with manual and haptic and/or active control modes
Inventors: Odermatt Daniel, Bassik Renen, Wu Chunyan, Landeck Danielle, Wojcik JasonAssignee: Odermatt Daniel, Bassik RenenFiled 2011-06-30 · Granted 2013-07-30

A surgical robotic system is disclosed that provides a combination of a programmed control, when a high degree of accuracy is required and manual control when a high degree of accuracy is not required.

US 2012209272 A1#13537612 Most Cited · 8 citations0.6/yr · PR 1.75PendingUS · Application
Haptic Volumes for Reaming During Arthroplasty

A haptic robotic system for reaming an acetabulum prior to inserting an acetabular cup is more accurate than conventional instruments and may reduce the risk of dislocation and improve durability of a hip implant. Disclosed is a three-dimensional tool path, referred to as a…

US 9,125,669 B2#33303975 Most Cited · 3 citations0.3/yr · PR 1.05ActiveUS · Utility
Haptic volumes for reaming during arthroplasty
Inventors: Ranawat Amar, Pagnano Mark, Dorr Lawrence, Jones Richard, Landeck DanielleAssignee: Ranawat Amar, Pagnano MarkFiled 2011-06-30 · Granted 2015-09-08

A haptic robotic system for reaming an acetabulum prior to inserting an acetabular cup is more accurate than conventional instruments and may reduce the risk of dislocation and improve durability of a hip implant. Disclosed is a three-dimensional tool path, referred to as a…

WO 2013/003095 A2#122240546 Most Cited · 0 citations0.0/yr · PR 0.56PendingWO · Application
Haptic volumes for reaming during arthroplasty

A haptic robotic system for reaming an acetabulum prior to inserting an acetabular cup is more accurate than conventional instruments and may reduce the risk of dislocation and improve durability of a hip implant. Disclosed is a three-dimensional tool path, referred to as a…

WO 2013/003095 A3#71767380 Most Cited · 0 citations0.0/yr · PR 0.56ActiveWO · Utility
Haptic volumes for reaming during arthroplasty

A haptic robotic system for reaming an acetabulum prior to inserting an acetabular cup is more accurate than conventional instruments and may reduce the risk of dislocation and improve durability of a hip implant. Disclosed is a three-dimensional tool path, referred to as a…